No ERR12 on startup, but ERR12 occurs during driving

  • Fault Cause: Controller malfunction or drive motor malfunction


    Troubleshooting Method: Using a multimeter to measure the drive motor resistance


    1. The normal resistance should be approximately 0.3-0.8Ω. If the resistance is abnormal, it indicates a malfunction of the drive motor, need replacement.


    2. Measure the resistance of the drive motor harness at the controller end: 

    The normal resistance should be approximately 0.3-0.8Ω. If the resistance is normal, it indicates controller malfunction, and the controller needs to be replaced.


    Tools Required: Multimeter

Step 1: Measure the motor resistance with a multimeter

Measure the motor resistance with a multimeter

Step 2: Measure the resistance of the drive motor

Measure Traction Motor Resistance