hyster

Err21

  • Fault Cause

    Accelerator or Monitor failure.


    When the accelerator is in the neutral position, the voltage is 2.5V ~2.6V. When the accelerator is rotated forward, the voltage gradually increases to 4.5V. When the accelerator is rotated backward, the voltage gradually decreases to 0.5V.


    Troubleshooting Method 1

    Enter the stacker diagnostic interface and observe the neutral position voltage value of the accelerator on the screen and the voltage changes when rotating the accelerator forward and backward. If the voltage changes do not match the above standards, it is judged as an accelerator failure. If the voltage matches the standards, it is judged as a Monitor failure.


    Troubleshooting Method 2

    Use a multimeter to measure the neutral position voltage of the accelerator and the voltage changes when rotating the accelerator forward and backward. If it does not match the above standards, it is judged as an accelerator failure. If the voltage matches the standards, it is judged as a monitor failure.



    Warranty Period:

    One year (not applicable for human - caused damages such as water ingress or collisions).


    Required information for warranty claims:

    1. Stacker nameplate photo;

    2. Photo of error code ( displayed on handle screen);

    3. Photo showing faulty component appearance

Step 1: Observe the accelerator voltage on the diagnostic interface

Observe the accelerator voltage on the diagnostic interface

Step 2: Measure the Accelerator Voltage with a Multimeter

Measure the Accelerator Voltage with a Multimeter