hyster

ERR27 at startup or during movement

  • Fault Causes:


    1.Brake cable disconnected or not plugged into controller.

    2.Controller failure.


    Troubleshooting Method:

    1.Visual Inspection: Check if brake cable is broken/damaged, or plug disconnected. Repair or reinsert if needed.


    ​2. Brake Resistance Measurement: Use a multimeter to measure brake resistance (Normal value: ~25Ω). Abnormal readings indicate brake or brake cable fault. 

    Replace or repair it.

    3.If above checks pass, confirm controller failure


    Solutions:


    Repair brake cable.

    Replace brake.

    Replace controller.


    Warranty Period:

    One year (not applicable for human - caused damages such as water ingress or collisions).

Step 1: Check Brake Cables & Connector

Check Brake Cables & Connector

Step 2: Measure brake resistance

Measure brake resistance