Battery Life Reduced to Only 1 Hour
Fault Causes:
1.Insufficient Charging Time (Not a defect, customer misjudgment)
Troubleshooting: Continue charging until the indicator light turns green. The battery level will reset to 100% after restarting.
2.Battery Failure
Troubleshooting:
Use multimeter to measure battery voltage
If the voltage of a single battery is lower than 7V, it is a serious discharge;
If the voltage difference between two batteries is greater than 0.7V, it indicates a battery failure.
Solution: Reactivate the battery or replace the 2 faulty batteries.
Warranty Period:
One year (not applicable for human - caused damages such as water ingress or collisions).
Required information for warranty claims:
1. Stacker nameplate photo;
2. Videos/photos of charging issues;
3. Photo showing faulty part